Depending on the SUT, the handling of the medication scheme may vary slightly.


R-10: Reading Gateway Validation Fails

Reading:

Before testing this, make sure you have uploaded the medication scheme.

...

  • The SUT keeps functioning in a normal fashion.
  • Either there should be no medications in the UI or print, or all 24 medications are present. The SUT should not display only a set of the medicationlines.
  • The user should be able to notice that there is an abnormality with his medication scheme.

...


W-15: Writing Gateway Validation Fails

Before testing this, make sure you have performed the 'R-10: Reading Gateway Validation Fails' part of the test.

Alter every medication by putting an extra dot (.) in the 'Instruction For Patient'. Then sync the altered medication scheme with Vitalink.

...