  1. Open the SUT and sync with Vitalink.

...

Expected Results(Reading):

  • TS-1: The SUT should be able to read the medicationscheme without problems.
  • TS-2: The patient print (and UI) should hold the same data as seen in the 'expected resultsVerification Screenshot' below.
  • TS-3: The caretaker print (and UI) should hold the same data as seen in the 'expected resultsVerification Screenshot' below.
  • TS-4: There is a medicationscheme with 4 medications.

...

  1. Make sure that the 'Reading' part of this test is performed first.
  2. Add a dot(.) in the 'instructionforpatient' field of each medication in the medicationscheme and then sync to Vitalink.

...

Expected Results:

  • TS-5: The alteration should have been written to Vitalink without causing errors or losing any data.
  • TS-6: The patient print (and UI) should hold the same data as seen in the 'expected resultsVerification Screenshot' below, with the added dots(.) in the 'instructionforpatient' field.
  • TS-7: The caretaker print (and UI) should hold the same data as seen in the 'expected resultsVerification Screenshot' below, with the added dots(.) in the 'instructionforpatient' field.
  • TS-8: There is a medicationscheme with 4 medications.

...

Verification Screenshot: