THIS SPACE IS UNDER CONSTRUCTION

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 28 Next »

General Information

Basic Flow

FlowSpecifications

IDAR-UC10-BF
NamePut Patient Consent - Authorized organization in behalf of HIO - Doctor
DescriptionA doctor working in the authorized organization that acts in behalf of a Health Insurance Organization (HIO) declares an Informed Patient Consent on behalf of the patient. Using the eHealth Certificate of the Authorized Organization to access the Consent WS. 
Actor(s)
  • A doctor working in the authorized organization
Requirements
  • End-user is a doctor working in the authorized organisation that acts in behalf of a HIO
  • The informed patient consent is managed by a recognized authorized organization through its usual software
  • Valid eHealth Certificate of the authorized organization
  • Consent WS is integrated in the software of the end-user
TriggerThe user wants to declare a Patient Consent in the behalf of a HIO
Precondition(s)
  • The user has an account for the application
  • The user is logged out
Flow
  1. The user attempts to access the eHealth Consent WS
  2. The user needs to request a SAML Token by using the eHealth Certificate of the Authorized Organization
  3. A request for a SAML Token is sent to the Secure Token Service (STS)
  4. The STS responds with a SAML Token
  5. The user has access to the eHealth WS Consent
  6. The user does a request for Put Patient Consent 
  7. The Put Patient Consent Request is sent to the WS Consent 
  8. ° The WS Consent responds with a Put Patient Consent Response

      ° The request is logged 

      ° The Informed Patient Consent is stored in eHealth Database

Post Conditions
  • Request is logged
  • Informed Patient Consent is stored in the eHealth Database
Test Data
Endpoint(s)
  • WS Consent
  • eHealth Database
RemarksThe identification of the Authorized organization is not mandatory in the Author of the request as the Trusted Third Party rule is applied

Alternative Flow

FlowSpecifications

IDAR-UC10-AF01
NamePut Patient Consent - Authorized organization in behalf of HIO - Administrative 
DescriptionAn administrative working under the responsibility of a doctor in the authorized organization that acts in behalf of a Health Insurance Organization (HIO) declares an Informed Patient Consent. Using the eHealth Certificate of the Authorized Organization to access the Consent WS.
Actor(s)
  • An administrative working in the Authorized Organization under the responsibility of a doctor 
Requirements
  • End-user is an administrative working in the Authorized Organization under the responsibility of a doctor 
  • The informed patient consent is managed by a recognized authorized organization through its usual software
  • Valid eHealth Certificate of the Authorized Organization
  • Consent WS is integrated in the software of the end-user
Trigger
Preconditions
Flow
Difference in flow
Post Conditions
Test Data
Endpoint(s)
RemarksThe identification of the Authorized organization is not mandatory in the Author of the request as the Trusted Third Party rule is applied
  • No labels