Scope

This page contains the Kmehrmessages for testing the behaviour of the SUT when transactions are put in the vault that do not conform to the recommended build of a transaction.

Instructions for EVS use:

IMPORTANT: This test has to be performed using the new version of EVS: EVSg

This EVS export file contains all the transactions used for this test.

Before starting the test, this export file should be uploaded using the EVS-action REPLACE and your own test patient.

The EVS parameter writeAsIs must be set to false.


Description:

After reading the medication scheme, the results can be verified in the SUT.

Depending on the SUT, the handling of the medication scheme may vary slightly.


Gateway Validation Fails


Reading:

Before testing this, make sure you have uploaded the medication scheme.

Verify the following:

  • The SUT keeps functioning in a normal fashion.
  • Either there should be no medications in the UI or print, or all PLACEHOLDER AMOUNT medications are present. The SUT should not display only a set of the medicationlines.
  • The user should be able to notice that there is an abnormality with his medication scheme.


Writing:

Before testing this, make sure you have performed the 'Reading' part of the test.

Alter every medication by putting an extra dot (.) in the 'Instruction For Patient'. Then sync the altered medication scheme with Vitalink.

Verify the following:

  • The SUT should have succesfully altered the medication scheme.
  • Either there should be no medications in the UI or print, or all PLACEHOLDER AMOUNT medications are present. The SUT should not display only a set of the medicationlines.
  • The user should be able to notice that there is an abnormality with his medication scheme.