THIS SPACE IS UNDER CONSTRUCTION

Used Documentation

Cookbook / Materials

Version

Location

Consent WS1.9https://www.ehealth.fgov.be/ehealthplatform/nl/service-ehealthconsent

General Information

Informed Consent 

The existence of an active ‘informed patient consent’ is one of the fundamental prerequisites for the healthcare providers to access patient’s medical data. Therefore, the eHealth platform makes available to the concerned patients and the health care actors involved in the exchange,

storage or referencing personal data a service to manage the ‘informed patient consent’ as defined by the deliberation 12/047 of the CSSSS/SCSZG1.

Technically, we identify the following attributes for an ‘informed patient consent’:

  • The SSIN of the patient.
  • The date of the consent registration (at the end-user side).
  • The “type” of the consent If the consent is only valuable for data posterior to the signing date, it is called ‘prospective’ and ‘retrospective’ in the other case . According to the rules defined now, the only possible value for this attribute is ‘retrospective’. The attribute is present for backwards compatibility.
  • The identity of the HCParty acting in the patient’s name (if applicable).


KMEHR

This service is a ‘KMEHR-based’ WS. We thus strongly recommend consulting the documentation related to the KMEHR normative elements. The KMEHR site aims to offer a central point for the documentation of the KMEHR normative elements.

https://www.ehealth.fgov.be/standards/kmehr/en

The three following generic elements are, in particular, essentials to build the request and the reply of eHealth Consent WS. 

Basic Flow

FlowSpecifications

IDUC-127-BF
NameRevoke Patient Consent - Group of nurses
DescriptionRevoke Patient consent allows end-users to revoke an active consent of the concerned patient. Request Revoke consent is done by a group of nurses.
Actor(s)Group of nurses
Requirements
  • End-user is a group of nurses
  • The Informed Patient Consent is managed within a group of nurses thru its usual software 
  • Valid eHealth Certificate of the Group of nurses
  • Consent WS is integrated in the software of the end-user
  • Identification group of nurses: NIHII number, professional category
  • Identification nurse: SSIN, NIHII (if available), professional category
  • Information about the consent to revoke

     °Identification data of concerned patient: SSIN, support card number, first and family name (optional)

     °Type of consent: retrospective

     °Date of revocation

TriggerThe user wants to revoke a Patient Consent 
Precondition(s)
  • The user has an account for the application
  • The user is logged out
Flow
  1. The user attempts to access the eHealth Consent WS
  2. The user needs to request a SAML Token by using his eID 
  3. A request for a SAML Token is sent to the Secure Token Service (STS)
  4. The STS responds with a SAML Token
  5. The user has access to the eHealth WS Consent
  6. The user does a request for Revoke Patient Consent 
  7. The Revoke Patient Consent Request is sent to the WS Consent 
  8. The revoked consent is stored in eHealth Database
  9. The request is logged 
  10. The WS Consent responds with a Revoke Patient Consent Response
Post Condition(s)
  • The request is logged 
  • The revoked consent is stored in eHealth Database with following information

         °SSIN of concerned patient 

         °Initial signing date of the consent

         °Consent type

         °Author of the request

         °Revocation date

Test Data
End point(s)
  • WS Consent
  • eHealth Database
RemarksIf concerned patient is a new-born (0 < patient < 3 months) the support card number is not mandatory
Additional InformationDate of revocation of an active consent must be equal or anterior to the request date. If so, it must be also anterior to the current date. 

Alternative Flow 1

FlowSpecifications

IDUC-127-AF01
NameRevoke Patient Consent - Group of nurses - Administrative
DescriptionRevoke Patient consent allows end-users to revoke an active consent of the concerned patient. Request Revoke consent is done by an administrative.
Actor(s)Administrative
Requirements
  • End-user is a administrative
  • The Informed Patient Consent is managed within a group of nurses thru its usual software 
  • Valid eHealth Certificate of the Group of nurses
  • Consent WS is integrated in the software of the end-user
  • Identification group of nurses: NIHII number, professional category
  • Identification nurse: SSIN, NIHII (if available), professional category
  • Identification administrative: SSIN number, professional category
  • Information about the consent to revoke

     °Identification data of concerned patient: SSIN, support card number, first and family name (optional)

     °Type of consent: retrospective

     °Date of revocation

TriggerThe user wants to revoke a Patient Consent 
Precondition(s)
  • The user has an account for the application
  • The user is logged out
Flow
  1. The user attempts to access the eHealth Consent WS
  2. The user needs to request a SAML Token by using his eID 
  3. A request for a SAML Token is sent to the Secure Token Service (STS)
  4. The STS responds with a SAML Token
  5. The user has access to the eHealth WS Consent
  6. The user does a request for Revoke Patient Consent 
  7. The Revoke Patient Consent Request is sent to the WS Consent 
  8. The revoked consent is stored in eHealth Database
  9. The request is logged 
  10. The WS Consent responds with a Revoke Patient Consent Response
Post Condition(s)
  • The request is logged 
  • The revoked consent is stored in eHealth Database with following information

         °SSIN of concerned patient 

         °Initial signing date of the consent

         °Consent type

         °Author of the request

         °Revocation date

Test Data
End point(s)
  • WS Consent
  • eHealth Database
RemarksIf concerned patient is a new-born (0 < patient < 3 months) the support card number is not mandatory
Additional InformationDate of revocation of an active consent must be equal or anterior to the request date. If so, it must be also anterior to the current date. 

Exception Flow 1

FlowSpecifications

IDUC-127-EF01
NameRevoke Patient Consent - Group of nurses - Deceased patient
DescriptionRevoke Patient consent allows end-users to revoke an active consent of the concerned patient. Request Revoke consent is done by a group of nurses. Deceased patient
Actor(s)Group of nurses
Requirements
  • End-user is a group of nurses
  • The Informed Patient Consent is managed within a group of nurses thru its usual software 
  • Valid eHealth Certificate of the Group of nurses
  • Consent WS is integrated in the software of the end-user
  • Identification group of nurses: NIHII number, professional category
  • Identification nurse: SSIN, NIHII (if available), professional category
  • Information about the consent to revoke

     °Identification data of concerned patient: SSIN, support card number, first and family name (optional)

     °Type of consent: retrospective

     °Date of revocation

  • Concerned patient is deceased
TriggerThe user wants to revoke a Patient Consent 
Precondition(s)
  • The user has an account for the application
  • The user is logged out
Flow
  1. The user attempts to access the eHealth Consent WS
  2. The user needs to request a SAML Token by using a eHealth Certificate 
  3. A request for a SAML Token is sent to the Secure Token Service (STS)
  4. The STS responds with a SAML Token
  5. The user has access to the eHealth WS Consent
  6. The user does a request for Revoke Patient Consent 
  7. The Revoke Patient Consent Request is sent to the WS Consent 
  8. The WS Consent responds with a Revoke Patient Consent Response: error message
Post Condition(s)Error message
Test Data
End point(s)
  • WS Consent
  • eHealth Database

Exception Flow 2

FlowSpecifications

IDUC-127-EF02
NameRevoke Patient Consent - Group of nurses - The consent of the concerned patient is already revoked
DescriptionRevoke Patient consent allows end-users to revoke an active consent of the concerned patient. Request Revoke consent is done by a group of nurses. The consent of the concerned patient is already revoked
Actor(s)Group of nurses
Requirements
  • End-user is a group of nurses
  • The Informed Patient Consent is managed within a group of nurses thru its usual software 
  • Valid eHealth Certificate of the Group of nurses
  • Consent WS is integrated in the software of the end-user
  • Identification group of nurses: NIHII number, professional category
  • Identification nurse: SSIN, NIHII (if available), professional category
  • Information about the consent to revoke

     °Identification data of concerned patient: SSIN, support card number, first and family name (optional)

     °Type of consent: retrospective

     °Date of revocation

  • The consent of the concerned patient is already revoked
TriggerThe user wants to revoke a Patient Consent 
Precondition(s)
  • The user has an account for the application
  • The user is logged out
Flow
  1. The user attempts to access the eHealth Consent WS
  2. The user needs to request a SAML Token by using a eHealth Certificate 
  3. A request for a SAML Token is sent to the Secure Token Service (STS)
  4. The STS responds with a SAML Token
  5. The user has access to the eHealth WS Consent
  6. The user does a request for Revoke Patient Consent 
  7. The Revoke Patient Consent Request is sent to the WS Consent 
  8. The WS Consent responds with a Revoke Patient Consent Response: error message
Post Condition(s)Error message
Test Data
End point(s)
  • WS Consent
  • eHealth Database

Exception Flow 3

FlowSpecifications

IDUC-127-EF03
NameRevoke Patient Consent - Group of nurses - The consent of the concerned patient does not exist
DescriptionRevoke Patient consent allows end-users to revoke an active consent of the concerned patient. Request Revoke consent is done by a group of nurses. The consent of the concerned patient does not exist
Actor(s)Group of nurses
Requirements
  • End-user is a group of nurses
  • The Informed Patient Consent is managed within a group of nurses thru its usual software 
  • Valid eHealth Certificate of the Group of nurses
  • Consent WS is integrated in the software of the end-user
  • Identification group of nurses: NIHII number, professional category
  • Identification nurse: SSIN, NIHII (if available), professional category
  • Information about the consent to revoke

     °Identification data of concerned patient: SSIN, support card number, first and family name (optional)

     °Type of consent: retrospective

     °Date of revocation

  • The consent of the concerned patient does not exist
TriggerThe user wants to revoke a Patient Consent 
Precondition(s)
  • The user has an account for the application
  • The user is logged out
Flow
  1. The user attempts to access the eHealth Consent WS
  2. The user needs to request a SAML Token by using a eHealth Certificate 
  3. A request for a SAML Token is sent to the Secure Token Service (STS)
  4. The STS responds with a SAML Token
  5. The user has access to the eHealth WS Consent
  6. The user does a request for Revoke Patient Consent 
  7. The Revoke Patient Consent Request is sent to the WS Consent 
  8. The WS Consent responds with a Revoke Patient Consent Response: error message
Post Condition(s)Error message
Test Data
End point(s)
  • WS Consent
  • eHealth Database
  • No labels