THIS SPACE IS UNDER CONSTRUCTION

Used Documentation

General Information

MetaHub

The ‘MetaHub’ component is introduced to support the interconnection between ‘Hubs’. This component is accessible to ‘recognized’ hubs. The word ‘hub’ denotes the kernel of a ‘recognized’ regional or sub regional health network.

The main purpose of the MetaHub is to allow a hub to know where it can find information about a patient outside of its network. More precisely, the MetaHub simply provides the list of hubs that have information about a patient. It is not the MetaHub’s role to know where, within a (sub)regional health network, the information is stored.

The MetaHub is thus more a ‘locator service’ than a ‘routing component’: there are no ‘document’ exchanges transiting throughout the component. MetaHub v2 also allows the hubs to consult and manage the registration of patient consents and exclusions1. A major feature is that the hubs themselves feed the MetaHub. See figure below.


KMEHR

This service is a ‘KMEHR-based’ WS. We thus strongly recommend consulting the documentation related to the KMEHR normative elements. The KMEHR site aims to offer a central point for the documentation of the KMEHR normative elements.

https://www.ehealth.fgov.be/standards/kmehr/en

The three following generic elements are, in particular, essentials to build the request and the reply of eHealth MetaHub WS.


Basic Flow

FlowSpecifications

IDUC-503-BF
NamePut Patient Consent - Professional of AR78
DescriptionA professional of AR78 declares the Informed Patient Consent through the Hub. Certificate used to access the MetaHub WS is the eHealth Certificate of the Hub. 
ActorsA professional of AR78 (! Only these 5 end-users: Physician - Nurse - Dentist - Midwife - Pharmacist)
Requirements
  • End-user is A professional of AR78 (! Only these 5 end-users: Physician - Nurse - Dentist - Midwife - Pharmacist)
  • End-user does the request throughout the hub
  • Valid eHealth certificate of the Hub
  • Identification of the hub: Hub ID, Organization category, Name (optional)
  • Identification of the end-user: SSIN number, NIHII number, Professional category, First and family name
  • Information consent: 

         °Patient SSIN

         °Patient SSIN Support card number (optional)

         °Date of registration of consent by patient

         °Type of consent: retrospective

TriggerThe user wants to declare a Patient Consent on behalf of the patient
Preconditions
  • The user has an account for the application
  • The user is logged out
Flow
  1. The user attempts to access to the eHealth MetaHub WS
  2. The user needs to request a SAML Token by using the eHealth Certificate of the Hub
  3. A request for a SAML Token is sent to the Secure Token Service (STS)
  4. The STS responds with a SAML Token
  5. The user has access to the eHealth WS MetaHub
  6. The user does a request for Put Patient Consent 
  7. The Put Patient Consent Request is sent to the MetaHub WS
  8. The Informed Patient Consent is stored in the MetaHub
  9. The request is logged 
  10. The MetaHub WS responds with a Put Patient Consent Response
Post Conditions
  • Request is logged
  • The informed patient consent is stored in the MetaHub
Test Data
End point(s)WS MetaHub
Remarks*Patient SSIN Support card number is optional, if provided then the card number is ignored (INSS and support card number are not submitted to status validation)
Additional InformationAdditional information of the hub as name is optional. If provided, it will be used for audit purposes.

Exception Flow

FlowSpecifications

IDUC-503-EF
NamePut Patient Consent - Professional of AR78 - There already exists an active consent for the concerned patient
DescriptionA professional of AR78 declares the Informed Patient Consent through the Hub. Certificate used to access the MetaHub WS is the eHealth Certificate of the Hub. There already exists an active consent for the concerned patient
Actor(s)A professional of AR78 (! Only these 5 end-users: Physician - Nurse - Dentist - Midwife - Pharmacist)
Requirements
  • End-user is A professional of AR78 (! Only these 5 end-users: Physician - Nurse - Dentist - Midwife - Pharmacist)
  • End-user does the request throughout the hub
  • Valid eHealth certificate of the Hub
  • Identification of the hub: Hub ID, Organization category, Name (optional)
  • Identification of the end-user: SSIN number, NIHII number, Professional category, First and family name
  • Information consent: 

         °Patient SSIN

         °Patient SSIN Support card number (optional)

         °Date of registration of consent by patient

         °Type of consent: retrospective

  • There already exists an active consent for the concerned patient
TriggerThe user wants to declare a Patient Consent on behalf of the patient
Precondition(s)
  • The user has an account for the application
  • The user is logged out
Flow
  1. The user attempts to access to the eHealth MetaHub WS
  2. The user needs to request a SAML Token by using the eHealth Certificate of the Hub
  3. A request for a SAML Token is sent to the Secure Token Service (STS)
  4. The STS responds with a SAML Token
  5. The user has access to the eHealth WS MetaHub
  6. The user does a request for Put Patient Consent 
  7. The Put Patient Consent Request is sent to the MetaHub WS
  8. The MetaHub WS responds with a Put Patient Consent Response: error message
Post Condition(s)Error message
Test Data
End point(s)WS MetaHub
  • No labels