Collision altering different medication

Preparation:

  1. Upload this EVS export file using the EVS-action REPLACE with PATIENT_A.
  2. Open the SUT and, using ACTOR_A, change the begindate of EVSREF100 to '01/04/2030'.
  3. Open another instance of the SUT and, using ACTOR_B, change the frequency of EVSREF101 to monthly. Then sync to Vitalink.
  4. Using ACTOR_A, try to sync to Vitalink.

...

Collision altering same medication same field

Preparation:

  1. Upload this EVS export file using the EVS-action REPLACE with PATIENT_A.
  2. Open the SUT and, using ACTOR_A, change the enddate of EVSREF102 to '31/12/2030'.
  3. Open another instance of the SUT and, using ACTOR_B, change the enddate of EVSREF102 to '01/06/2031'. Then sync to Vitalink.
  4. Using ACTOR_A, try to sync to Vitalink.

...

Collision altering same medication different field

Preparation:

  1. Upload this EVS export file using the EVS-action REPLACE with PATIENT_A.
  2. Open the SUT and, using ACTOR_A, change the begindate of EVSREF103 to '01/04/2030'.
  3. Open another instance of the SUT and, using ACTOR_B, change the dayperiod of EVSREF103 to 'during breakfast'. Then sync to Vitalink.
  4. Using ACTOR_A, try to sync to Vitalink.

...

Collision adding medication

Preparation:

  1. Upload this EVS export file using the EVS-action REPLACE with PATIENT_A.
  2. Open the SUT and, using ACTOR_A, change the begindate of EVSREF104 to '01/04/2030'.
  3. Open another instance of the SUT and, using ACTOR_B, add a new medication and give it EVSREF107. Then sync to Vitalink.
  4. Using ACTOR_A, try to sync to Vitalink.

...

Collision removing medication

Preparation:

  1. Upload this EVS export file using the EVS-action REPLACE with PATIENT_A.
  2. Open the SUT and, using ACTOR_A, change the begindate of EVSREF105 to '01/04/2030'.
  3. Open another instance of the SUT and, using ACTOR_B, remove EVSREF106. Then sync to Vitalink.
  4. Using ACTOR_A, try to sync to Vitalink.

...