...
This EVS export file contains all the transactions used for this test.Before starting the test, this export file should be uploaded using the EVS-action REPLACE and your own
test patientThe tests will explain what to do with the export file.
The EVS parameter writeAsIs must be set to false.
...
R-10: Reading Gateway Validation Fails
Before testing this, make sure you have uploaded the medication schemeUpload the medicationscheme using the EVS-action REPLACE and your own test patient.
Verify the following:
- TS-1: The SUT keeps functioning in a normal fashion.
- TS-2: Either there should be no medications in the UI or print, or all 24 medications are present. The SUT should not display only a set of the medicationlines.
- TS-3: The user should be able to notice that there is an abnormality with his medication scheme.
...
- TS-1: The SUT should have succesfully altered the medication scheme.
- TS-2: Either there should be no medications in the UI or print, or all 24 medications are present. The SUT should not display only a set of the medicationlines.
- TS-3: The user should be able to notice that there is an abnormality with his medication scheme.
W-20: Writing Single Validation Fail
This test will require you to upload every medicationline separately.
The export file will contain comments that show where a medicationline starts and where it ends. Separate that part (and close the remaining open tags) and put it in a separate file (don't forget to include the header information and medicationscheme transaction). That separate file has to be uploaded using the EVS-action REPLACE and your own test patient. This has to be done for each medicationline. Each medicationline should be in a format similar to this: